La boulonnerie

Les dimensions.

Standard

Les dimensions standard La colonne couple de serrage correspond au standard pour une vis de classe 8.8 (la plus courante) avec un coefficient de frottement moyen de μ=0,14 (vis légèrement huilée).
VIS/ECROU
ISOPasd2d3As
mm²
PerçageClé HHauteur
Ecrou
Clé BTR8.810.912.9
Couple
Nm
F0
kN
Couple
Nm
F0
kN
Couple
Nm
F0
kN
M1M0.25M0.838M0.6930,4600.752.50.80.70.0170.240.0250.3500.0290.413
M2M0.4M1.74M1.5092,0731.641.61.50.351.050.5111.5330.6021.806
M3M0.5M2.675M2.3875,0312.55.52.42.51.22.41.7523.5042.0644.128
M4M0.7M3.545M3.1418,7773.373.232.74.23.9426.1324.6447.224
M5M0.8M4.48M4.01914,1834.284.745.56.88.0309.9289.46011.696
M6M1M5.35M4.77320,1215105.259.59.613.87014.01616.34016.512
M8M1.25M7.188M6.46636,6066.75136.862317.633.58025.69639.56030.272
M10M1.5M9.026M8.1657,9948.5168.484627.967.16040.73479.12047.988
M12M1.75M10.863M9.85384,26410.251810.8107940.7115.34059.422135.88070.004
M14M2M12.701M11.546115,437122112.81212555.7182.50081.322215.00095.804
M16M2M14.701M13.546156,666142414.81419576.1284.700111.106335.400130.892
M20M2.5M18.376M16.933244,79417.5301817390118.8569.400173.448670.800204.336
M22M2.5M20.38M18.93303,41419.53219.417530147.2773.800214.912911.600253.184
M24M3M22.051M20.319352,490213619.419530171.1773.800249.806911.600294.292
M27M3M25.05M23.32459,391244123.8191000225.11,460.000328.6461,720.000387.172
M30M3.5M27.727M25.706560,59526.54621.5221350272.21,971.000397.4122,322.000468.184
M33M3.5M30.727M28.706693,56229.55023.8241850339.42,701.000495.5243,182.000583.768
M36M4M33.402M31.093816,737325525.6272350398.73,431.000582.1024,042.000685.764
M42M4.5M39.077M36.4791,120,90237.565343238005505,548.000803.0006,536.000946.000
M48M5M44.752M41.8661,473,147437538365700726.58,322.0001,060.6909,804.0001,249.580
M50M5M46.752M43.8661,612,348458040366500797.99,490.0001,164.93411,180.0001,372.388
Calcul Rappel sur les types d'écrous :
  • Écrou standard ($m\approx 0,8\cdot d$) : C'est celui du tableau ci-dessus.
  • Écrou bas ($m\approx 0,5\cdot d$) : ISO 4035. Utilisé principalement comme contre-écrou.
  • Écrou haut ($m\approx 1\cdot d$) : Utilisé pour des assemblages soumis à de fortes tractions.
  • $d_2~et~d_3$​ : Calculés selon la norme ISO avec $H=0,866\cdot P$.
  • Effort de maintien (F0​) : Calculé avec $F_0​=0,75\cdot As​\cdot Re$.
  • $As$​ est la section résistante : $As\approx \dfrac{4}{\pi}(\dfrac{d_2+d_3}{2})$.
  • Re​ (limite élastique) : 640 MPa (8.8), 940 MPa (10.9), 1100 MPa (12.9).
  • Couples : Les valeurs en Nm sont données pour un coefficient de frottement global de $K=0,14$ (souvent pris à 0,20 pour du montage à sec) $C=K\cdot d\cdot F_0$​
    .